Parameter Call Duration Count Start Time
Default 0s
Value Range 0-60 s
Description/Function Specifies the length of time in seconds the system is to wait after
sending all dialling digits to the Central Office before starting the
call duration count.
Note
• The elapsed time of the call duration is shown on a display
PT.
Reference • 1.3 System Features (F/G)
– Station Message Detail Recording (SMDR)
Parameter First Digit Time
Default 10 s
Value Range 5-120 s
Description/Function Specifies the maximum time allowed between the start of an
outside dial tone and the first digit dialled on an outgoing call.
Reference None
Parameter Inter-digit Time
Default 5s
Value Range 1-30 s
Description/Function Specifies the maximum time allowed between each digit on an
outgoing call.
Note
• This timer applies to the call until the Toll Restriction check
is completed.
Reference None