Бесплатные инструкции на русском языке
  • Тип техники
  • Бренд

Просмотр инструкции атс Panasonic KX-TD500, страница 186

Panasonic
Line
186 Programming Guide
Parameter Card No.
Default
Value Range XXX : YYY [XXX : Card No. (101-314), YYY : Card Type]
Description/Function Specifies the physical number of the extension card and its type,
which you are going to programme.
Reference • 1.2 Slot Assignment (P/G)
Parameter Port No.
Default 1
Value Range 1-n [n = 4(OPX), 8(PLC/HLC/SLC/SLC-M), 16(DLC/DHLC/
ESLC), 24 (T1[OPX])]
Description/Function Specifies the extension port which you are going to programme.
Note
Port Nos. 17-32 will be displayed when "DN" and "Group
No." for "Ext No.2" are assigned in "1-4 VPS (DPT) Port
Assignment" screen (Section 1.5).
Reference • 1.4 Extension Port Assignment (P/G)
Parameter DN
Default
Value Range 3-4 digits consisting of 0-9
Description/Function Specifies the extension which you are going to programme.
Reference • 1.4 Extension Port Assignment (P/G)
• 2.3 Numbering Plan (P/G)
Parameter Group No.
Default (Display only)
Value Range 1-128
Description/Function Displays the Extension Group to which the selected extension port
is assigned.
Note
Default Group No. for Ext. 1001 is 128.
Reference • 1.4 Extension Port Assignment (P/G)
• 3.3 Extension Group (P/G)