Programming Error Messages
346 Programming Guide
E2013 Invalid directory number for Operator FDN.
Only FDN of an extension group and incoming group can be assigned as an Operator
FDN.
E3001 Invalid directory number for intercept destination.
There are six possible destinations for intercepted calls:
(1) An extension, (2) an external pager (TAFAS), (3) an OGM group,
(4) an extension group, (5) an incoming group, or (6) a phantom extension.
E3002 Invalid directory number for overflow destination.
Only DN of an extension or FDN of an extension group, an incoming group, a phantom
extension or an external pager (TAFAS) can be assigned as an overflow destination.
However, the type of DN / FDN assignable depends on "Group Type."
E3003 Invalid directory number for UCD supervisor extension.
Only DN of an extension can be assigned as UCD supervisor extension.
E3004 Extension group number duplicated.
Each extension group in the same paging group must have a unique number.
E3005 The extension group already belongs to another paging group.
An extension group cannot belong to two or more paging groups.
E3006 Invalid directory number for Incoming group destination.
Only DN of an extension or FDN of an extension group can be assigned as an Incoming
group destination.
E3008 Invalid directory number for DISA built-in Automated Attendant Tables.
Both DN of extensions and FDN of extension groups, incoming groups, phantom
extensions, or TAFAS can be assigned as DISA built-in Automated Attendant Tables.
E3009 Incoming group destination duplicated.
The directory number (of the extension or extension group) must be unique as a
destination.
E3010 Invalid Mailbox Number.
Only DN of an extension or FDN of an extension group can be assigned as a Mailbox
Number.
E4003 Invalid LCS playback password.
The LCS playback password must be 3 digits (0–9).
E4004 Invalid Call Log lock password.
The Call Log lock password must be 3 digits (0–9).
E4005 Invalid Station Lock password.
The Station Lock password must be 3 digits (0–9).
E4006 Specify trunk line no.
Trunk line no. must be specified when Single-CO key is assigned.
Error Code