Просмотр инструкции атс Panasonic KX-TD500, страница 128
Group
128 Programming Guide
Parameter Flash Time
Default 80 ms: [SA], 600 ms: Others
Value Range
1. None
2. 80 ms
3. 300 ms
4. 600 ms
5. 900 ms
6. 1200 ms
Description/Function Specifies the length of flash time.
Notes
• When you need finer resolution, assign this to 80 ms and use
"Flash Time" parameter in "1-1 Slot Assignment - Card
Properties (XXX: ELCOT)" screen.
• You must use "Flash Time" parameter in "1-1 Slot
Assignment - Card Properties (XXX: ELCOT)" screen when
your Central Office requires a Flash Time not listed here.
• For information on "Card Properties" screen, please refer to
"Card Type" in Section "1.2 Slot Assignment."
Reference None
Parameter Disconnecting Time
Default 1.5 s
Value Range
1. 0.5 s
2. 1.5 s
3. 2.0 s
4. 4.0 s
5. 12.0 s
Description/Function Specifies the maximum time in seconds the system is to wait after
releasing the trunk line before getting it again.
Note
• This allows the Central Office an opportunity to release its
resources before another trunk call is placed from the PBX.
Reference None