Бесплатные инструкции на русском языке
  • Тип техники
  • Бренд

Просмотр инструкции автомойки Karcher CB 2 23, страница 37

Karcher
- 15
19 CAN bus error, module A14, no connec-
tion (water distributor)
Loose connecting chord of the plates,
plates defective
Switch off and switch on the unit, repeat
washing process, call Customer Service
20 CAN bus error, module A13, no connec-
tion (feed distributor)
21 CAN bus error, module A11, no connec-
tion (in main switching cabinet CB2)
22 CAN bus error, module A12, no connec-
tion (in main switching cabinet CB2)
23 CAN bus error, module A7, no connection
(water distributor CB2)
24 CAN bus error, module A21, no connec-
tion (anti-frost)
25 CAN bus error, module A22, no connec-
tion (underbody washing)
26 CAN bus error, module A23, no connec-
tion (gate control)
27 CAN bus error, module A24, no connec-
tion (gate control)
28 CAN bus error, module A25, no connec-
tion (washing phase display)
29 CAN bus error, module A26, no connec-
tion (Interface wash card reader in feed
distributor)
30 CAN bus error, module A27, no connec-
tion (high pressure pump)
31 CAN bus error, module A28, no connec-
tion (external dosing pumps)
32 Excess current outlets CAN Bus module
A10 (main plate)
Short circuit, water leakage
35 Excess current outlets CAN Bus module
A14 (water distributor)
36 Excess current outlets CAN Bus module
A13 (feed distributor)
37 Excess current outlets CAN Bus module
A11 (in main switching cabinet CB1)
38 Excess current outlets CAN Bus module
A12 (in main switching cabinet CB1)
40 Excess current outlets CAN Bus module
A21 (anti-frost)
41 Excess current outlets CAN Bus module
A22 (underbody cleaning)
42 Excess current outlets CAN Bus module
A23 (gate control)
43 Excess current outlets CAN Bus module
A24 (gate control)
44 Excess current outlets CAN Bus module
A25 (washing phase display)
Short circuit, water leakage Switch off and switch on the unit, repeat
washing process, call Customer Service
45 Excess current outlets CAN Bus module
A26 (Interface wash card reader in feed
distributor)
46 Excess current outlets CAN Bus module
A27 (high pressure pumps)
47 Excess current outlets CAN Bus module
A28 (external dosing pumps)
48 EE_prom not read Error in main plate Switch off and switch on the unit, repeat
washing process, call Customer Service
49 E_prom checksum error
Display Fault Possible cause Remedy
37EN
Ваш отзыв будет первым
Задайте вопрос
Ваше имя
E-mail
Вопрос*
Ваш вопрос будет опубликован после проверки
Ваш вопрос опубликован

Смотрите также другие инструкции раздела Автомойки

Смотрите также другие инструкции раздела Karcher