Просмотр инструкции кофеварки Vitek VT-1518 BK, страница 6

Vitek
6
ENGLISH
DESCALING
For effective operation of the coffee maker we
recommend removing scale every 2-3 months
and more often when using “hard” water.
1. Make citric acid solution:
2. 2 teaspoons and 1 l of water and pour this
solution into the water tank (2). Install the
water tank (2) to its place.
3. Insert the coffee filter (15) into the holder (9).
4. Install the filter holder into the coffee maker.
The holder (9) ledges should match the
groves on the boiler, after that turn the filter
holder (9) handle to the right until bumping.
5. Place a suitable cup on the tray grid (8).
6. Insert the power plug into the mains socket.
7. Switch the coffee maker on by pressing the
power switch button (5) «
».
8. Wait until the ready light (11) will be glowing
constantly.
9. 9. Set the switch (12) knob to the position « »
and fill a cup of about 100 ml capacity with
water (it is necessary to drain the water from
the boiler and fill the boiler with citric acid
solution), switch the water supply off by set-
ting the switch (12) knob to the position «О».
10. Remove the tip (6) from the cappuccinator
pipe (4) and put a suitable bowl under the pipe
(4). Wait until the indicator (5) lights up, then
switch the steam supply on for approximately
1 minute by setting the switch (12) knob to the
position «
», after that switch the steam sup-
ply off by setting the switch (12) knob to the
position «О» and switch the coffee maker off
by pressing the power switch button (5)
.
Wait for 10-15 minutes.
11. Repeat the procedure described in steps 7-10
not less than 3 times.
12. Switch the coffee maker on by pressing the
power switch button (5) «
».
13. Wait until the ready light (11) lights up.
14. With small intervals, repeat the boiler cleaning
procedure (clause 9) until the citric acid solu-
tion dissolves in the water tank completely.
15. Fill the water tank (2) with clear water and
repeat the clauses 7-10 not less than 3 times
without the 10-15 minute break.
16. Switch the coffee maker off by pressing the
power switch (5) button «
».
Note: to remove the scale you can use special
descaling agents for coffee makers and coffee
machines, strictly following the instructions on
their usage.
CLEANING
If during the filter (15) cleaning you find out
that the openings are blocked with the ground
coffee remnants, you can clean them with a
small brush.
Clean the coffee maker body with a soft,
slightly damp cloth and then wipe it dry.
Do not use metal brushes or abrasives to
clean the coffee maker.
Do not immerse the power cord, the power
plug and the coffee maker body into water or
other liquids.
Wash the removable parts of the coffee maker
with warm water and neutral detergent, then
rinse them and dry.
Drip tray (7)
Remove the grid (8) from the tray (7), remove
the tray (7) and pour out water, wash the tray
(7) and put it back to its place, put the grid (8)
on the tray.
TROUBLES AND TROUBLESHOOTING
Problem Cause Solution
The unit can’t be
switched on
No voltage in the mains socket.
The power plug is not completely inserted
into the socket.
Make sure that the plug is
operating.
Check whether the plug is
completely inserted into the
socket.
Water leaks from
the lower part of
the coffee maker
The water tray is full. Pour out water from the tray.
Coffee leakage
from the filter
holder
Untight connection of filter and boiler
gasket, ground coffee got on the edges of
the filter.
Clean the edges of the filter.
IM VT-1518.indd 6 15.08.2017 14:23:09