Просмотр инструкции стиральной машины Beko WRE 6412 ZWW, страница 38

Beko
38 / EN
Washing Machine / Users Manual
The hose should be attached to a height of at least 40 cm,
and 100 cm at most.
In case the hose is elevated after laying it on the floor level
or close to the ground (less than 40 cm above the ground),
water discharge becomes more difficult and the laundry
may come out excessively wet. Therefore, follow the heights
described in the figure.
To prevent flowing of dirty water back into the machine and
to allow for easy discharge, do not immerse the hose end
into the dirty water or do not drive it in the drain more than
15 cm. If it is too long, cut it short.
The end of the hose should not be bent, it should not be stepped on and the hose must not be pinched
between the drain and the machine.
If the length of the hose is too short, use it by adding an original extension hose. Length of the hose may
not be longer than 3.2 m. To avoid water leak failures, the connection between the extension hose and
the drain hose of the product must be fitted well with an appropriate clamp as not to come off and leak.
2.6 Adjusting the feet
A WARNING: In order to ensure that the product operates more silently
and vibration-free, it must stand level and balanced on its feet. Balance the machine
by adjusting the feet. Otherwise, the product may move from its place and cause
crushing and vibration problems.
1. Loosen the lock nuts on the feet by hand.
2. Adjust the feet until the product stands level and balanced.
3. Tighten all lock nuts again by hand.
A
WARNING: Do not use any tools to loosen the lock nuts. Otherwise, they will get damaged.
2.7 Electrical connection
Connect the product to a grounded outlet protected by a 16 A fuse. Our company shall not be liable for
any damages that will arise when the product is used without grounding in accordance with the local
regulations.
Connection must comply with national regulations.
Power cable plug must be within easy reach after installation.
If the current value of the fuse or breaker in the house is less than 16 Amps, have a qualified electrician
install a 16 Amp fuse.
The voltage specified in the "Technical specifications" section must be equal to your mains voltage.
Do not make connections via extension cables or multi-plugs.
B
WARNING: Damaged power cables must be replaced by the Authorized Service Agents.
Transportation of the product
1. Unplug the product before transporting it.
2. Remove water drain and water supply connections.
3. Drain all water that has remained in the product.
4. Install transportation safety bolts in the reverse order of removal procedure.
C
Never move the product without the transportation safety bolts properly fixed in place!
A
WARNING: Packaging materials are dangerous to children. Keep packaging materials in a safe place away
from reach of the children.