Просмотр инструкции весов Saturn ST-PS0283, страница 4
6
• The digits on the display will flash
before your exact weight will be shown.
• In order to extend the battery life,
the device will automatically turn off 10
seconds after you have stepped off the
scale.
Saving Personal Data
NOTE:
• The scale has default values that you
can change, as described below.
• Carry out the following steps in
sequence and within a few seconds.
Otherwise, the device will
automatically cancel input mode.
• Press the button SET. The memory
space will flash on the display
(USER0.Confirm the setting by pressing
SET or select another memory space by
pressing the UP/DOWN button. Then
press SET to go to the next setting.
• The symbol for "male" or "female" will
flash. Confirm the setting by pressing
SET or use the UP/DOWN button to
choose the symbol for your gender.
Then press to go the next setting.
• The height setting will flash. Select
your height by pressing UP or DOWN
button. Holding down one of the buttons
will accelerate the process. Confirm your
entry by pressing SET.
• The setting AGE will flash. Select your
age by pressing UP or DOWN button.
Holding down one of the buttons will
accelerate the process. Confirm your
entry by pressing SET.
NOTE:
• The device can only function correctly
if you stand on the device with bare, dry
feet!
• If necessary wipe the contact surface
improve results.
• Due to the significant fluctuation of
body fat, it is different to attain a
standard value. On average the optimal
testing time is between 6 p.m. and 8
p.m., since the body fat remains very
consistent during this period of time.
• Press the SET button. The preset
stored position date appears on the
display9USER flash). Use the UP/DOWN
button to select the stored position at
which your date is saved.
• Wait for the USER display and 0.0kg
(0.0lb/st) to stop flashing.
• Stand on the contact surfaces (1) of
the scales with both feet.
• Firstly your weight will flash on the
display.
• After a few seconds, the following
results will be shown:
1. -the body fat content in % (FAT
symbol)
-the body water content in % (TBW
symbol)
-the results analysis in the form of a
bar
2 -the muscle mass content in %
(MUS symbol)
-the bone mass content in % (BON
symbol)
-the calorie requirement per day
3 -The present gender
-The present type
-The present height
-The present age (AGE)
Display error Message
NOTE;
If an error message appears on the
display, wait until the device is turned
off. Turn it on again to restart the
operation. If the error display has not
disappeared, take the batteries out of
the battery compartment for 10
seconds.
Display symbol Meaning
8888 Self-test (when
switching on) to
check that the
numeric display
functions properly
---- The scales stand
faultily
Lo Battery is low
Err The percentage of
body fat content
lies above or below
the limits of the
measuring scale
EEEE The weight lies
above the allowed
maximum weight
Cleaning
•Clean the device with a slightly moist
cloth. Make sure that no humidity or
waters seeps into the device.
•Use a commercially sold
detergent or soap for cleaning.
•Dry the device well after cleaning
with a dry and soft cloth.
7
Technical Specifications
Model: ST-PS0283
Power supply: batteries 1.5V
Type "AAA"/R03"
Net weight of device: 2KG
Memory capacity: 10
Height alignment: from 75 to 225 cm
(2'5"-7'41/2 "Ft; in)
Age: from 10 to 85 years
Minimum weight:
from 2.5kg (5.5lb/0; 4st)
Maximum weight:
150Kg (330.7lb/23; 6st)
Weight measurement unit:
100g increments
Body fat measuring unit: 0.1%
Body fat measuring range:
4.0%-50.0%
Body water measuring range: 35.0%-
85.0%
Muscle mass measuring:
1.0%-50.0%
Subject to technical changes without
prior notice!
This device has been tested according to
all relevant current CE guidelines, such
as electromagnetic compatibility and low
voltage directives, and has been
constructed in accordance with the
latest regulations.
SET
Bathroom Scales 1
Instruction Manual with
Warranty Book 1
Package
1
ENVIRONMENT FRIENDLY
DISPOSAL
You can help protect the
environment!
Please remember to respect
the local regulations: hand in
the non-working electrical
equipment to an appropriate
waste disposal center.
The manufacturer reserves the right
to change the specification and
design of goods.
RU
Напольные весы с анализатором
жировой массы
Уважаемый покупатель!
Поздравляем Вас с приобретением
изделия торговой марки “Saturn”.
Уверены, что наши изделия будут
верными и надежными
помощниками в Вашем домашнем
хозяйстве.
Не подвергайте устройство резким
перепадам температур. Резкая
смена температуры (например,
внесение устройства с мороза в
теплое помещение) может
вызвать конденсацию влаги
внутри устройства и нарушить его
работоспособность при
включении. Устройство должно
отстояться в теплом помещении не
менее 1,5 часов. Ввод устройства в
эксплуатацию после
транспортировки производить не
ранее, чем через 1,5 часа после
внесения его в помещение.
Содержание:
Общие правила техники
безопасности
Обозначения, используемые в данной
инструкции
Дети
Меры предосторожности при
обращении с весами
Использование батареек
Установка батареек
Расположение кнопок управления
Технические характеристики
Информация об измерении
жировой ткани
Жировая ткань
Значимость воды для нашего
здоровья
Общие нормы
Использование
Функция взвешивания
Сохранение данных пользователя
Анализ результатов
Отображение сообщений об
ошибках
Очистка
Общие правила техники
безопасности
Внимательно прочтите данную
инструкцию перед началом
использования прибора. Храните
инструкцию вместе с гарантией,
кассовым чеком, а также, если это
возможно, коробку с внутренними
упаковочными материалами. В случае
передачи Вами этого прибора другим
людям, также передайте инструкцию
по эксплуатации.
· Данный прибор предназначен
исключительно для личного, а не
коммерческого использования
· Используйте прибор только по
назначению
· Не используйте повреждённый
прибор
· Не подвергайте прибор
Ваш отзыв будет первым