Бесплатные инструкции на русском языке
  • Тип техники
  • Бренд

Просмотр инструкции насосы Al-ko JET 60005 PREMIUM, страница 17

Al-ko
Help in case of malfunction
467 774_a 17
Special mode
In order to use a Hydrocontrol or a remote control switch, the pump must start automatically, the special
mode must be actuated for this.
Switching condition LED display Function description
Activating the special mode: Keep
the START/STOP button depressed for
10 seconds when inserting the mains
plug.
All LED displays
flash.
Pump now starts immediately. Mode
is retained, even when removing the
mains voltage. Special mode active
when LED display PUMP ON flashes
in operation.
Activating the special mode:Keep
the START/STOP button depressed for
10 seconds when inserting the mains
plug.
All LED displays
flash.
Pump switches off immediately. Start
again by pressing the START/STOP
button
Fault message
LED display LED display Function description
Pump switches off by the electronics
(dry running protection). Reset the
fault message by pressing the START/
STOP button.
LED display
ALARM lights up.
Check suction line, then back to initial
commissioning until the pump delivers
water.
Dry running alarm: This message is
displayed if no flow is measured for
longer than 180 seconds. Reset the
fault message by pushing the START/
STOP button.
During the first and second re-start af-
ter the fault message.
LED display
ALARM flashing
Check pump and back to initial com-
missioning until the pump delivers wa-
ter.
During the third re-start after the fault
message.
LED displays
FLOW CONTROL
and LED display
ALARM flash al-
ternately.
Allow the pump to cool down and
check.
HELP IN CASE OF MALFUNCTION
CAUTION!
Disconnect the mains plug before any fault rectification work!
Malfunction Possible cause Rectification
Dry running protection activated Check suction side
Impeller blocked Remove dirt from suction area
Pump drive motor
does not run
Thermal protection switch has swit-
ched off.
Wait until the garden pump is switched
on again by the thermal switch.
Take account of the maximum tempe-
rature of the conveying medium. Have
the garden pump checked out.