Maintenance and care
477 296_b 19
Unscrew float body
1. Pressure line (Fig. B -8) with elbow nipple
(Fig. B -10) and connecting nipple (Fig. B -12)
must be unscrewed.
2. Unscrew screw-in nipple (Fig. D -21) with seal
(Fig. D -22) . Note the fitting position of the
float body (Fig. D -23) . Pull out the float body
and clean it.
3. Replace the float body - note fitting position
(Fig. D).
Remove blockages
1. Isolate the unit from the mains and secure
against switching on again.
2. Remove the suction hose from pump inlet.
3. Connect the pressure hose to the water sup-
ply.
4. Allow water to run through the pump housing
until the blockage is removed.
5. Check that the pump is running freely by swit-
ching it on briefly.
6. Start the house water system again as descri-
bed.
STORAGE
ADVICE
If there is a risk of frost, the entire sys-
tem must be drained (pump, lines, stor-
age vessel and filter chamber).
1. Drain the suction line (Fig. B -14) and the
pressure line (Fig. B -8).
2. Unscrew the drain screws (Fig. A -6/A-6a) and
allow the water to flow out of the pump.
3. Screw the drain screws (Fig. A -6/A-6a) back
in position and store the pump, lines and sto-
rage vessel in a frost-free environment.
DISPLAY INDICATIONS
On initial commissioning, all information appears on the display in English.
All functions can be called up using the MODE button. The displays/functions called up are confirmed
with the SET button.
ADVICE
The information in the second line of the display is partially shown as running text which provides
running information continuously.
Normal operation and additional functions
Setting the language
Display indicator Switching condition Function / actions
ENGLISH
Pump running or switched
off
Press the MODE button for longer than 3 se-
conds, the operating language is activated.
Change the operating language by pressing the
MODE button (30). Confirm the new operating
language by pressing the SET button.
Initial start-up of the unit
Display indicator Switching condition Function / actions
AUTO 0
FLOW
0 L/H
Pump ready Pump starts automatically when water is drawn
off.
Pump runs in normal operation
Display indicator Switching condition Function / actions
Ваш отзыв будет первым
Задайте вопрос
Ваше имя
E-mail
Вопрос*
Ваш вопрос будет опубликован после проверки
Ваш вопрос опубликован
Посетитель_Gs99qg
Вопросы пользователей
Поиск:
по производителю
по типу техники
по модели
Сортировать:
по дате
c ответами
Искать
Гость
07 июня 2019, Санкт-Петербург
какой объем воды заливается в насос al-ko hwa 4000 comfort
Гость
07 июня 2019, Санкт-Петербург
какой объем воды заливается в насос al-ko hwa 4000 comfort
Гость
20 мая 2019, Кировск
не заливается вода в насос, образовалась пробка. как устранить?