1-16
SERVICE AND MAINTENANCE
Open the front panel.
Hold the panel at the recesses on the main unit
(2 recesses on right and left sides) and lift it until it
stops.
1.
Remove the front panel.
While lifting the front panel further, slide it to the right
and pull it to the front side. The left rotating shaft is
detached. Slide the right rotating shaft to the left and
pull it to the front side to remove it.
2.
Attach the front panel.
Align the right and left rotating shafts of the front panel
with the grooves and push them all the way in.
Gently close the front panel. (Push both ends and the
center on the front panel.)
3.
Service Parts Maintenance Procedures Period
Indoor air filter Remove any dust adhering to the filter by using a vacuum cleaner or wash in lukewarm
water (below 40°C/104°F) with a neutral cleaning detergent.
Rinse the filter well and dry before placing it back onto the unit.
Do not use gasoline, volatile substances or chemicals to clean the filter.
1.
2.
3.
At least once
every 2 weeks.
More frequently
if necessary.
Indoor unit Clean any dirt or dust on the grille or panel by wiping it with a soft cloth soaked in
lukewarm water (below 40°C/104°F) and a neutral detergent solution.
Do not use gasoline, volatile substances or chemicals to clean the indoor unit.
1.
2.
At least once
every 2 weeks.
More frequently
if necessary.
! CAUTION
Avoid direct contact of any coil treatment cleaners on plastic part. This may cause plastic part to deform as a result
of chemical reaction.
Note is valid for Turkey only: The lifetime of our products is ten (10) years
! CAUTION
Don’t touch the metal parts of the indoor unit. It may cause an injury.
When removing or attaching the front panel, support the panel securely with hand to prevent it from falling.
For cleaning, do not use hot water above 40°C, benzine, gasoline, thinner, nor other volatile oils, polishing
compound, scrubbing brushes, nor other hand stuff.
After cleaning, make sure that the front panel is securely fixed.
Step Step
Front Panel Opening & Closing Sequence
To open the front panel
1) Lift up the two tips of front panel 1 until it stops at the pre-fix position.
2) Lift up the two tips of front panel 2 to open it and access to inner parts.
To close the front panel, reverse the steps of opening sequence
Rotating shaft
Recess on
main unit
1 IM-5WMYJR-1114(2)DK VZ-EN-418216 161 IM-5WMYJR-1114(2)DK VZ-EN-418216 16 3/25/15 3:18:20 PM3/25/15 3:18:20 PM
Ваш отзыв будет первым