- 18
Brief instruction SB-WASH
Adjustment control circuit
board
Menue point adjustment Option Standard
setting
Adjust
Warm-Water Progr. 1 warm/ cold warm
Progr. 2 cold
Progr. 3 warm
Progr. 4 cold
Time-Base Time-Base: 30...300 s 90 s
Wash-Time Progr. 0 100...50% 100%
Progr. 1 60%
Progr. 2 90%
Progr. 3 70%
Progr. 4 60%
Progr. 5 60%
Coin-Amount Channel 1: 10...200 10
Channel 2: 20
Channel 3: 40
Channel 4: 10
Channel 5: 20
Channel 6: 40
Options Halfload On/Off Off
Osmosis Off
Data
Version Version: x.x
Statistics Coin
Counter
Today: Coins
Total: Coins
*)
Timer
HP-Pump
Total: hours
S001: hours
S002: hours
Timer Burner Total: hours
S010: hours
S020: hours
Timer-Pro-
grams
Progr 1: hours
Progr.2: hours
Progr.3: hours
Progr.4: hours
Progr.5: hours
Error
Message
Error: Exxx
Service Service:
Sxxx
*) Reset coin sum- daily counter: Push the "<" and ">" for two
seconds at the same time.
Interruptions and service
announcements control
circuit board
Error
codes
Cause
E001 Motor protection switch -Q1 or development temper-
ature switch of the HD-Pumpe has triggered off
Winding protection contact motor
E002 Fuse - F1 has triggered, circulating pump, heat fan
E003 Interruption warm water heater
E004 Osmosewater is empty (Option)
E005 Cleaning agent container/fluel empty /Option)
E100 Interruption control circuit
Servicecode Meaning Intervall
S001 pump head HD-pump 250 h
S002 HD-Pump totally 500 h
S010 Burner lid ( starter) 250 h
S020 fuel valve, burners are blacking 500 h
Menue navigation
Button Action
OK, for 2 seconds open the menue
<, > change values, turn menue
OK Confirm
ESC cancel, exit
Brief Instructions
for maintenance and
servicing
Please pay attention to the section "maintenance and serv-
ice" in the operation instructions!
DAILY
Checl high pressure hose
check brush
Check information notices in the equipment
Check the pipe line and high pressure pump for tightness
Check the content of the cleaning agent container
Check the content of the fuel container
DAILY IF FROST
Check and if needed clean the fan heater and the anti freeze cycle
After 40 operating hours, or weekly
Check oil level of the high pressure pump
Check the oil condition of the high pressure pump (is there water
in the oil?)
Clean the brush shaft and the floaing container
EVERY 14 DAYS
Clean and service the housing of the total equipment
After 160 operating hours, or monthly
Clean the coin mechanism.
Clean the filter of the cleaning agent container
Grease the joints at the doors
AFTER 250 OPERATING HOURS OR SEMI-ANNUALLY
Check pump head (Customer Service)
Adjust ignition electrode, replace if required (customer service)
BEFORE THE FROST PERIOD
Check the anti freeze equipment of its function
BEFORE THE FROST PERIOD AND DURING THE FROST
PERIOD MONTHLY
Check the freezing water amount
After 500 operating hours, or yearly
Change the oil and high pressure pump
Clean the soot of the heating coils and decalcify (Maintenance)
Adjust burner (Customer Service)
Clean the fuel container
base exchanger (optional)
Pay attention to the saltusage, check daily
Refill the salt, if the water level is above the salt
Check salt container, remove sludge
The suction jet of the salt container must be put to the grounf of
the container
The gree light at the E-equipmentboard is blinking => base ex-
changer does regenerate
PROPORTION EQUIPENT HAS TO BE DECALCIFIED RM
110 (OPTION)
Pay attenetion to the amount used of the RM110, check daily
Red light at the E-equipment board => container empty
Remove this page, cut above this field, und put it inside the door of the control board. A copy of this brief