c) Minimum regulation of the hob b urners:
Turn the tap to minimum;
Remov e the knob and adjust the regulation scre w,
which is positioned in or ne xt to the tap pin, until the
flame is small b ut steady.
NB.: In the case of liquid gas, the regulation screw
must be screwed in all the way.
Check that the flame does not go out when you turn
the tap quickly from high to lo w.
d) Regulating the primary air of the burners: the primary
air of the burners does not need to be regulated.
Burner and Nozzle Specifications
Tabl e 1 Liqui d Gas Natural Gas
Burner Diameter
(mm)
Thermal P ower
kW (p.c.s .*)
By- Pa s s
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Nominal Reduced (mm) (mm) *** ** (mm) (mm)
Fast
(Large)(R)
100 3.00 0.7 41 86 218 214 116 286 143 286
Semi Fa s t
(Medium)(S)
75 1.90 0.4 30 70 138 136 106 181 118 181
Auxiliar y
(Small)(A)
55 1.00 0.4 30 50 73 71 79 95 80 95
Supply
Pre ssur es
Nominal (mbar)
Minim um (mb ar )
Maxi mum (mb ar )
28-30
20
35
37
25
45
20
17
25
13
6,5
18
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S . = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
S
S
R
A
K6 G52S/R
Important
On completion of this operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessar y to fit a
suitable pressure regulator onto the inlet pipe in compli-
ance with current standards regarding “regulators for chan-
nelled gas.”.