Gas connection
Gas connection must be carried out accord-
ing to the rules in force. The manufacturing
company release the unit, once tested, ad-
justed for the kind of gas stated on the rating
plate located on the back of the range, next
to connection pipe. Be sure that you are go-
ing to connect the unit to the same kind of
gas written on the plate.
Installation environment
Warning! This unit can be installed and
can work only in constantly ventilated
rooms, according to rules in force.
In order to make the gas unit work properly,
it is necessary that air sufficient to gas com-
bustion can naturally flow in the room. (The
installer must follow the rules in force).
The air flow into the room must come directly
through openings of external walls. These
openings (or opening) should be realized in
such a way not to be occluded both from in-
side and outside.
Installation and maintenance must be carried
out by a qualified technician, in compliance
with rules in force.
The electric connection must be carried out
in compliance rules in force.
Important! Our responsibility will not be
involved in case of accidents caused by a
defective or non existent earth connection.
Combustion products discharge
Gas cooking units must discharge combus-
tion products through hoods directly con-
nected to flues or outside.
Connection using a rigid pipe or a
flexible metal pipe
To ensure higher safety, it is recommended
to carry out the connection to the gas system
using rigid pipes (ex. copper) or using flexible
stainless steel pipes, to avoid any stress to
the unit. Gas feeding pipe fitting is Gc 1/2.
For this type of installation, connection to the
gas supply should be carried out using only
and exclusively flexible metallic tubes in con-
formity with rules in force.
Connection using flexible non metal
pipes
When the connection can be easily inspec-
ted in its full extent, there is the chance to use
a flexible pipe according to the rules in force.
The flexible pipe must be tightly fixed using
clamps according to the rules in force.
The flexible pipe should be made ready for
use in such a way that:
nowhere it can reach over temperature,
other than room temperature, higher than
30
°
C; if the flexible pipe, to reach the cock,
must run behind the range, it must be in-
stalled as shown below;
it is no longer than 1500 mm;
it shows no throttles;
it is not subject to traction or torsion;
it does not get in touch with cutting edges
or corners;
it can be easily inspected in order to check
its condition.