10. Troubleshooting
BREAKDOWN ANALYSIS SOLUTIONS
No voltage input Check the fuse and breaker
Improper fuse or breaker Replace the fuse and breaker
No current output
Over load protective is triggered Continue until cooling down
Have no enough pressure Tighten the impaction nut
Bad wire feed
Wire has been oxide Replace wire spool
Input voltage is too poor
Check that if input voltage is the
same with rated volatge
Bad connection
Check grounding cable man
make sure well connection
Current is too poor
One or more commute element
have been damaged
Contact the Service Center
No gas or little gas Check all gas
The hole has been blocked Use compress air to clear spoil
Valve has been blocked
Open the welding torch and
check
The welding line is
like sponge
Bad gas and wire
Gas must be dry, use another
type wire
Control wire broke off Contact the Service Center
When the switch is
on, the machine
can not work
PCB is damaged Contact the Service Center