OPERATION
STARTING GENERATOR
WARNING: Before starting the generator, be sure that you read and understand all the safety and
operating instructions of the Generator Instruction manual.
1. Disconnect all electrical loads from the generator and
place the AC no fuse breaker in the OFF (“OPEN”)
position.
2. Open the fuel cock.
3. Set the choke lever to “CLOSE” (arrow mark).
Not necessary if the engine is warm.
4. Turn the engine switch to “START” position, and hold it
there until the engine starts.
When the engine starts, release the key, allowing the
switch to return to the “RUN (I)” position.
If the engine fails to start within 5 seconds, release the
key, and wait at least 10 seconds before operating the
starter again.
NOTE: Use short starting cycles (15 seconds per
minute) to prolong starter motor life. Extended
cranking can damage starter motor.
5. After the engine started, return the choke lever gradually
to “OPEN” position.
6. Warm up the engine without a load for a few minutes..
NOTE: If the oil level in the engine is low, the engine will not start. If the engine does not start, check the
oil level and add oil as needed.
NOTE: To ensure maximum oil lubrication, place the generator on a level surface.
OPEN
CLOSE
OFF
RUN
START
OPEN