c) Minimum regulation of the hob b urners:
•
turn the tap to minimum;
• remove the knob and adjust the regulation screw , which
is positioned in or ne xt to the tap pin, until the flame is
small b ut steady.
N.B.: in the case of liquid gas, the regulation screw
must be scre w ed in to the bottom.
• check that the flame does not tur n off when you tur n
the tap quic kly from high to lo w.
d) Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
Adapting the gas oven to diff erent types of gas
a) Replacing the ov en b urner nozzle:
• remov e the w arming drawer;
• remov e the sliding protection “A” (see Fig.C);
• remove the screw and then the oven burner “V”(see
Fig. D). Remove the oven door to facilitate this
operation.
• unscrew the oven burner nozzle using the special
socket spanner for the nozzles (see Fig. E), or better
still a 7 mm socket spanner , and replace it with a nozzle
suited to the new type of gas (see table 1).
Fig. C Fig. D
Fig.E
b) Minimum regulation of the gas oven burner with
thermostat (see fig.):
• light the burner as described in the paragraph “the oven
knob” of the instruction booklet.
• turn the knob to Max for about 10 minutes and then
turn the knob to the Min setting;
• remov e the knob;
• regulate the scre w positioned outside the thermostat
pin until the flame is small but steady.
N.B.: in the case of liquid gas, the regulation screw
must be scre w ed in to the bottom.
Adapting the gas grill to different types of gas
Replacing the nozzle of the grill burner:
• remove the screw and then slide out the grill burner “V”
(see Fig. F);
• unscrew the grill burner nozzle using the special socket
spanner for the nozzles (see Fig. G) or better still a 7 mm
socket spanner; replace the nozzle with a nozzle for the new
type of gas (see table 1).
Fig. F Fig. G
Pay particular attention to the plug wires and
thermocouple tubes.
Important
On completion of the operation, replace the old rating
stick er with one indicating the new type of gas used. This
stick er is availab le from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
“regulators f or channelled gas”.