Electrical connection
Before plugging in, ensure that the voltage and frequency
shown on the serial number plate correspond to your
domestic power supply.
Voltage can vary by ±6% of the rated voltage.
For operation with different voltages, a suitably sized
auto-transformer must be used.
II
Important
The appliance must be earthed.
The power supply cable plug is provided with a contact
for this purpose.
If the domestic power supply socket is not earthed.
connect the appliance to a separate earth in compliance
with current regulations, consulting a specialist
technician.
The Manufacturer declines all responsibility if the
above safety precautions are not observed.
This appliance complies with the following
E.E.C.
Directives:
- 87/308 EEC of 2/6/87 relative to radio interference
suppression.
- 73/23 EEC of 19.2.73 (Low Voltage Directive) and
subsequent modifications.
- 89/336 EEC of 3.5.89 (Electromagnetic
Compatibility Directive) and subsequent
modifications.
II
Attention!
It must be possible to disconnect the appliance
from the mains power supply; the plug must therefore be
easily accessible after installation.
Building-in
Dimensions of the recess
Height of housing (1)
880 1225 mm
Depth of housing (2)
550 550 mm
Width of housing (3)
560 560 mm
Installation
Take utmost care when handling your
appliance so as not to cause any damages to
the cooling unit with consequent possible fluid
leakages.
During normal operation, the condenser and
compressor at the back of the appliance heat up
considerably. Always ensure that there is adequate
ventilation as a failure to do this will result in
component failure and possible food loss. See
installation instructions.
Important: if the supply cord is damaged, it must be
replaced by a special cord or assembly available
from the manufacturer or its service agent.
Positioning
Unpack the cabinet and check that it is in good
condition and free of any transport damage.
The appliance must not be located close to radiators
or gas cookers.
Avoid prolonged exposure of the appliance to direct
sunlight.
For safety reasons, minimum ventilation must be as
shown in Fig.
Attention: keep ventilation openings clear of
obstruction.
It is necessary that the niche is provided with a
conduct of venti-lation having the following
dimensions:
Depth: 50 mm
Width: 540 mm
The climate classification can be found on the rating
plate, which is located inside the cabinet on the left hand
wall.
The following table shows which ambient temperature is
correct for each climate classification:
Climate for an ambient
classification temperature of
SN +10 to +32 °C
N +16 to +32 °C
ST +16 to +38 °C
T +16 to +43 °C