GGBB
Something not Working
Problems may be due to causes which can easily be
solved before calling the Technical Service. Please follow
these instructions:
SYMPTOM
Door does not close
It is too warm inside the refrigerator
It is too cold inside the refrigerator.
The compressor works continuously.
There is water inside/outside the refrigerator.
Water comes out on the floor.
Noises
SOLUTION
Level properly the appliances if it is not well levelled.
Weight surpasses the storage limit of the door shelf so spread weight more evenly or take
some products out.
The appliance is not properly installed. Please look in the “Building-in” section.
Set a lower temperature.
Distribute the food products to allow cold air to circulate around them.
Make sure that the door is completely closed and that the insulating strip is complete and
clean.
The temperature where the cabinet is placed is above normal room temperature.
Turn the temperature regulator to a warmer setting temporarily.
Turn the thermostat knob to a lower number.
The temperature where the cabinet is placed is above normal room temperature.
Check that the ventilation is sufficient and that the ventilation openings are unobstructed.
The cause could be the introduction of large quantities of food and/or frequent
opening/closing of the door.
Sometimes is normal. During automatic defrosting frost thaws on the cooling plate.
Place the drain hose at the back of the cabinet above the drain bowl.
Sometimes this is normal. Temperature control may cause clicking sounds when the system
is connected or disconnected.
The injected cooling gas may produce a gurgling sound while passing through the tubes.
The motor may cause a humming noise and/or slight bumping.
The insulation material used has a tendency to slighly increase noise levels, how ever it allows
for much better insulation and a lower energy consumption.