Бесплатные инструкции на русском языке
  • Тип техники
  • Бренд

Просмотр инструкции кондиционера Samsung AW05B0LA (AW0519), страница 2

Samsung
4-2 Samsung Electronics
4-2 Checking the Oil
4-2-1 Oil quality
4-2-2 Changing and adding refrigerant oil
1. Change the compressor - DO NOT recharge the oil as the compressor itself is
already charged.
2. Change the condenser .... add 50cc
3. Change the evaporator .... add 50cc
4. When the refrigerant is replaced .... add 30cc oil.
5. After vacuum is completed, the oil is filled through the high pressure side.
6. In the event of a refrigerant leak, generally it is not necessary to add oil
(unless the oil has leaked significantly).
Put approximately 10cc oil into a transparent container and test it.
4-3 Refrigerant Oil Specifications
Normal
Overheat
Motor Damage
Condition of
Refrigerant Cycle
Color
Light Yellow
Brown Color
Dark Brown
No Odor
-
Pungent Oil
Odor
Remarks
Return with the system
Oil Change
Oil Change
Condition of Oil
Model Oil Specification Oil Change
AW05B0LA(AW0519) SONTEX 200LT 280CC
AW-05B0LA(AW0519)-1 11/27/98 2:05 PM Page 4-2