Просмотр инструкции атс Panasonic KX-TD500, страница 350
Programming Error Messages
350 Programming Guide
E9001 Invalid directory number for DDI / DID destination.
There are seven possible destinations for DDI / DID calls:
(1) An extension, (2) an external pager (TAFAS), (3) an OGM group,
(4) a remote extension, (5) an extension group, (6) an incoming group, or
(7) a phantom extension.
E9002 Page length must be 4 lines more than Skip Perforation.
The difference of Page Length and Skip Perforation must be more than 4 lines.
E9003 Trunk or extension card duplicated.
Under Power Failure Transfer, a trunk card or an extension card can be specified only
once.
E9004 Assign both trunk card and extension card.
Cannot assign just trunk card or just extension card.
Both must be assigned as a pair under Power Failure Transfer.
E9005 Time or date format error.
The invalid value of time or date is entered.
E9006 Invalid System Programming password.
Please assign the 4 through 7-digit System Programming password of alphanumeric
characters.
E9007 Invalid User Programming password.
Please assign the 4 through 7-digit User Programming password consisting of 0–9.
E9008 Invalid Walking COS password.
Please assign the 4 through 7-digit Walking COS password consisting of 0–9.
E9009 DDI / DID / MSN number duplicated.
Each DDI / DID / MSN number in "9-1 Number Transformation" screen must have a
unique number.
E9010 Number of DDI dial must be equal to or less than 16 digits.
The total digits of "Base Number" and "Number of Digits" are over 16.
E9011 Beginning Entry No. must be equal to or less than 991.
Cannot specify the number "992-999" as the "Beginning Entry No." because "Number
of Registrations" is set by 10 entries increments, and the number of available entries
are limited to 1000.