Programming Guide 105
Parameter 28. Trunk hunting mode
Default Forced
Value Range
1. Forced
2. Loop Detection
Description/Function Specifies the trunk hunting mode.
1. Forced
The system seizes a trunk line whether or not loop current is
detected from the local CO.
2. Loop Detection
The system seizes a trunk line after detecting loop current from
the local CO.
Reference • 3.2 Trunk Group (P/G)
Parameter 29. Card CODEC
Default Mu Law
Value Range
1. Mu Llaw
2. ALaw
Description/Function Specifies the PCM (Pulse Code Modulation) conversion mode of
KX-T96xxx series trunk and extension cards.
Note
This setting is required only when XMX (for Mexico) type
KX-T96xxx series trunk and extension cards are installed in
the system. In this case, select "A Law."
Reference None
Parameter 30. Net CODEC
Default Mu Law: [HK], A Law: Others
Value Range
1. Mu Law
2. ALaw
Description/Function Specifies the type of PCM (Pulse Code Modulation) conversion
mode compatible with the Digital Network to which the system is
connected.
Note
The change of this parameter is activated after resetting the
system.
Reference None