Просмотр инструкции измерительного прибора Condtrol Laser 3D, страница 15
15
Laser 3D CONDTROL
CROSS-LINE LASER
User Manual
TECHNICAL DATA
Automatic levelling range ± 5°
Accuracy ± 3 mm / 10 m
Operating range (depending on room
illumination)
20 m
Laser wavelength 635 nm
Laser class / line laser output power 2M / < 5 mW
Power supply 4 x 1,5V AA / ca. 20 h
Dimensions / weight (without wall bracket
and batteries)
122 x 100 x 70 mm / 0,55 kg
Temperature range, operating / storage 0°C ... +50°C / -10°C ... +70°C
Note: Regularly check the calibration before use, after transport and after
extended periods of storage.
THE CALIBRATION CHECK
It is possible for you to check the calibration of the laser. To do this, position
the device midway between 2 walls, which must be at least 5 metres apart. Do
this by turning the unit on, thus releasing the transport restraint (cross laser on).
Please use a tripod.
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark point A2. You now have a horizontal
reference between points A1 and A2.
Ваш отзыв будет первым