Просмотр инструкции измерительного прибора Condtrol XLiner Combo, страница 16

Condtrol
XLiner / XLiner Combo CONDTROL
XLiner / XLiner Combo CONDTROL
30
31
user manual user manual
EN EN
TECHNICAL DATA
Parameter Value
Working range/with detector 50m/100m*
Leveling accuracy ±0.2mm/m
Self-leveling range ±5°
Leveling duration, typically <4 sec
Operating temperature -20°C…+50°C
Storage temperature -40°C…+70°C
Relative air humidity, max 90%
Laser type 635nm, <1 mW
Laser class II
Tripod mount 1/4'', 5/8''
Batteries 3x1.5V LR6 (AA)
Operating life time 20 hours
Automatic switch-off 60 min
Weight 0.39kg
Dimensions 131x74x113mm
* An operating range can be different from the stated above subject to
light conditions
OPERATION
• Protect the instrument from moisture and direct sunlight.
• Protect the instrument from extreme temperatures and temperature
fluctuations. Do not leave the instrument, for example, in a car for a long
time. At large temperature fluctuations, before switching-on, it is necessary
to wait until the temperature aligns.
• Protect the instrument from blows and falls. After a strong external
influence on the instrument it is always necessary to check accuracy before
starting the work again (See «Accuracy Check»).
Switch off the instrument during transportation. Always switch the On/Off D
to the right position. When switching off, the leveling unit, which can be
damaged in case of intense movement, is locked.
Switch on/off
Press the button 1 to switch on the instrument.
By consecutive pressing 1 the instrument is switched to the different
operating modes displayed on the keypad (horizon; vertical; horizon and
vertical at the same time; defining of directions; horizon, vertical, defining
of directions at the same time).
To work with the automatic compensation switch on the instrument as it
is described above and switch the On/Off D to the outside left position.
Switching of the operating modes also is made by pressing 1.
At a low charge of the batteries the indicator 3 flashes red.
- Do not direct the laser beam on people or animals and do not look
in the laser beam, even from a long distance.
- Do not leave the switched-on instrument unattended and switch
it off after using.
To switch off the instrument move the On/Off D to the right position,
at this the leveling unit is blocked, press and hold the button 1 within 2
seconds.